Technical Data | HIH-30K-TT | HIH-50K-TT | HIH-60K-TT | HIH-100K-TT | HIH-125K-TT | HIH-150K-TT |
PV Input | ||||||
Maximum Input Voltage | 850 V | |||||
MPPT Voltage Range | 600~850 V | |||||
Number of MPPT | 3 | |||||
Maximum Input Power Per MPPT | 10 kW | 20 kW | 30 kW | |||
Battery Input | ||||||
Battery Type | Lithium, Lead-Acid, Lead-Carbon, etc. | |||||
Voltage Range | 320~600 V | 400~600 V | ||||
AC Output (On-Grid) | ||||||
Rated Output Power | 30 kW | 50 kW | 60 kW | 100 kW | 125 kW | 150 kW |
Maximum Output Power | 33 kVA | 55 kVA | 66 kVA | 110 kVA | 137 kVA | 165 kVA |
Rated Grid Voltage | 230/400 V (3PH, N, PE) | |||||
Rated Grid Frequency | 50/60 Hz | |||||
AC Output (Off-Grid) | ||||||
Rated Output Power | 30 kW | 50 kW | 60 kW | 100 kW | 125 kW | 150 kW |
Maximum Output Power | 33 kVA | 55 kVA | 66 kVA | 110 kVA | 137 kVA | 165 kVA |
Overload Capacity | 110%, 10min / 120%, 1min | |||||
Rated Grid Voltage | 230/400V (3PH, N, PE) | |||||
Rated Grid Frequency | 50/60 Hz | |||||
THDi (Rated Power) | <3% | |||||
Unbalanced Load Capacity | 100% | |||||
General Data | ||||||
Maximum Efficiency | 92% | 93% | 94% | |||
Protection | AC Short Circuit Protection, DC Reverse Polarity Protection, Surge Protection (PV-side & Grid-side) | |||||
Ingress Protection Rating | IP20 | |||||
Isolation Transformer | Yes | |||||
Temperature Range | -30~55ºC | |||||
Cooling Method | Forced Air Cooling | |||||
Relative Humidity | 0~95%, Non-condensing | |||||
Altitude | ≤5000 m (>3000 m Derating) | |||||
Display | Touch Screen | |||||
Communication | Ethernet, RS485 | |||||
BMS Communication | RS485, CAN | |||||
Communication Protocol | Modbus RTU/TCP | |||||
Standby Consumption | <50 W | |||||
Weight | 650 kg | 650 kg | 800 kg | 900 kg | 1050 kg | 1250 kg |
Dimensions (WxDxH) | 950x700x1953 mm | 1200x800x2050 mm |
Commercial
Commercial Hybrid Inverter (Built-in Transformer, 30kW / 50kW / 60kW / 100kW / 125kW / 150kW)
- Multi-channel PV MPPT access to improve power generation utilization
- Power frequency topology, industrial design
- Wide DC input voltage range design, compatible with different batteries
- High-performance DSP, optimized control circuit design, better performance
- Intelligent management control strategy, multiple working modes, online or remote switching
- Cold start with load, three-phase 100% unbalanced load, strong load adaptability
- Supports diesel generator access, seamless switching between on-grid and off-grid (optional)
- AC and DC dual power backup, ensure the power supply of the control system