Technical Data | HIH-4K-TL | HIH-5K-TL | HIH-6K-TL | HIH-8K-TL |
PV Input | ||||
Maximum Input Power | 6 kW | 7.5 kW | 9 kW | 12 kW |
Start-up Voltage | 200 V | |||
Maximum Input Voltage | 1000 V | |||
MPPT Voltage Range | 180~960 V | |||
MPPT Working Voltage For Full Load | 220~850 V | 250~850 V | 320~850 V | 360~850 V |
Number Of MPPT / Strings Per Channel | 2/1 | |||
Maximum MPPT Input Current | 25 A (12.5/12.5) | |||
Battery Input | ||||
Battery Type | Lithium, Lead-Acid | |||
Number Of Battery Input | 1 | |||
Voltage Range | 180~800 V | |||
Voltage Range For Full Load | 200~800 V | 200~800 V | 240~800 V | 320~800 V |
Maximum Charge/Discharge Current | 25 A | |||
Communication | CAN, RS485 | |||
Battery Charging Strategy | According to BMS instructions / 3 Stages (Lead-Acid) | |||
AC Output (On-Grid) | ||||
Rated Output Power | 4 kW | 5 kW | 6 kW | 8 kW |
Maximum Output Power | 4.4 kVA | 5.5 kVA | 6.6 kVA | 8.8 kVA |
Rated Output Voltage | 220/380V, 230/400V (3PH, N, PE) | |||
Output Voltage Range | 184~276 V | |||
Maximum Output Current | 6.5 A | 8 A | 10 A | 13 A |
Output Frequency | 50/60 Hz (45~54.9 / 54.9~65) | |||
Power Factor | 1 (0.8 leading~0.8 lagging) | |||
THDi (Rated Power) | <3% | |||
Backup AC Output (EPS) | ||||
Rated Output Power | 4 kVA | 5 kVA | 6 kVA | 8 kVA |
Maximum Output Power | 4.4kVA 60s, 6kVA 1s | 5.5kVA 60s, 7.5kVA 1s | 6.6kVA 60s, 9kVA 1s | 8.8kVA 60s, 12kVA 1s |
Maximum Output Current | 6.5 A | 8 A | 10 A | 13 A |
Rated Output Voltage | 220/380V, 230/400V (3PH, N, PE) | |||
Output Frequency | 50/60 Hz (±0.2%) | |||
THDu (Linear Load) | <3% | |||
Automatic Switching Time | <10 ms | |||
General Data | ||||
Maximum Efficiency | 98% | |||
Protection | DC Lightning Protection, AC Lightning Protection, PV Reverse Polarity Protection, Battery Reverse Protection, Insulation Resistor Detection, Leakage Current Detection, Anti-island Protection, Grounding Fault, Input Overvoltage & Unervoltage, Output Overvoltage & Unervoltage, Input Overcurrent, Output Overcurrent, Overheat Protection | |||
Ingress Protection Rating | IP65 | |||
Noise | <40 dB | |||
Temperature Range | -25~60ºC | |||
Cooling Method | Natural Cooling | |||
Relative Humidity | 0~95% | |||
Altitude | ≤4000 m (>2000 m Derating) | |||
Display | LCD | |||
Communication | RS485, CAN (Standard); Wi-Fi (Optional) | |||
BMS Communication | RS485, CAN | |||
Standby Consumption | <15 W | |||
Grid Standard | VDE4105/EN50549 | |||
Safety Standard | CE/IEC62109 | |||
Weight | 26 kg | |||
Dimensions (WxDxH) | 540x240x450 mm |
Residential
Three-Phase Hybrid Inverter (4kW / 5kW / 6kW / 8kW)
- Compatible with different batteries, perfect protection function and strong environmental adaptability
- Wide DC input voltage range design
- Multi-channel PV MPPT access to improve power generation utilization
- Off-grid output connection unbalanced load, supports three phase independent output
- Ingress protection IP65, wall mounted design
- Battery reverse polarity protection
- Compatible anti-backflow function
- Seamless switching between off-grid and on-grid
- Maximum efficiency up to 98%
- Multiple working mode: Self-use mode, Time-of-use mode, Timing mode, Passive mode
- Remote monitoring of PC and mobile phones